CP500 DC Power Modules for
Impressed Current Cathodic Protection Applications |
|
| |
|
|
| |
 |
|
| |
- Versatile, robust and reliable design
- 25V/20A, 50V/10A, 100V/5A options available
- Built-in programmable interrupter supplied as standard
- Ultra-low output ripple
- Constant voltage, current and potential modes
- Built-in alarm and system events log (1000 entries)
- Built-in potential measurements log (over 7000 entries)
- Optional upgrade modules available for GPS
synchronization, potential measurements log expansion,
local and remote communications
- Simple to use multi-functional controls for programming
- VFD or LCD display
|
|
| |
|
|
|
| |
|
|
|
| |
 |
|
| |
INPUT
AC Voltage Range Current
Frequency
Power Factor
Efficiency
Inrush Current
Soft Start
Protection
|
85-264VAC single-phase
6.5A rms max at 85VAC
45-66Hz
>0.98 at 40-100% load
>90% at >50% output power
<8A peak at nominal mains volts
Power on ramp-up time <5 secs
Surge protection varistors
Inrush limiting circui
|
|
| |
OUTPUT

Voltage Range
Current Range
Potential Range
Ripple
Protection
|

100mV to full volts (100mV steps)
10mA to full current (10mA steps)
0V to -2.5V
<20mV (in voltage mode)
Temperature limited
Internal fuse
EMC filtering
Surge suppression on line |
|
| |
|
|
|
| |
|
|
|
| |
 |
|
| |
Dimensions:
Weight:
|
80x175x245mm (power module)
100x300x350mm (with interface)
<2.5kg (power module)
<6.0kg (with interface)
|
|
| |
|
|
|
| |
|
|
|
| |
 |
|
| |
Cooling:
Temperature:
Humidity:
|
Natural Convection
-20°C to +55°C (operating)
-40°C to +70°C (storage)
0 to 90% non-condensing
to 1500 metres
|
|
| |
|
|
|
| |
|
|
|
| |
 |
|
| |
All alarms are indicated by an alarm LED, relay contact closure and/or digital comms to external monitoring |
|
| |
Mains too low
Output open circuit
High output volts
Low output volts
Voltage out of range
Low output current
Under-protection
Potential out of range
|
Always active
Always active
User select/program
User select/program
User select/program
User select/program
User select/program
User select/program |
|
| |
|
|
|
| |
|
|
| |
 |
|
| |
GPS module for remote interrupter synch
Potential measurements log expansion module
USB port for local communication
TCP/IP module for remote communication
GSM module for remote communication
|
|
| |
|
|
|
| |
 |
|
| |
|
|
|
| |
|
|