CP1400 DC Power Modules for
Impressed Current Cathodic Protection Applications |
|
| |
|
|
| |
Note: The CP1400 rectifier is controlled and monitored by a CP Controller (CPC). |
|
| |
|
|
| |
 |
|
| |
- Versatile, robust and reliable design
- 30V/52A and60V/34A options available
- Ultra-low ripple for enhanced accuracy
- Constant voltage and current modes
|
|
| |
|
|
|
| |
|
|
|
| |
 |
|
| |
INPUT
AC Voltage Range
Current RMS
Frequency
Power Factor
Efficiency
Inrush Current
Soft Start
Protection
|
90-275VAC single-phase
Full Power above 150VAC
14A @ 150VAC, 9A @ 230VAC
45-66Hz
>0.98 at 40-100% load
>90% at >50% output power
<8A peak at nominal mains volts
Power on ramp-up time 8 secs
Shutdown >300VAC
Indefinite survival @ 400VAC
HRC input fuse for both lines
Surge protection varistors
|
|
| |
OUTPUT

Voltage Range
Current Range
Static Regulation
Dynamic Regulation
Noise
Load Sharing Protection |

1.0V to full voltage
0.1A to full current
Line - better than ±0.02%
Load - better than ±0.05%
±5.0% for 10-90-10% load steps
±1.0% of final value <1ms of step
±0.1% for 25% step change in AC
<2mV RMS Psophometric
<10mV MS and <100mV peak to
Better than ±5% of full scale
Fused output
Reverse polarity
Live connection surges
Over-voltage
Over-current
Over-temperature |
|
| |
|
|
|
| |
|
|
|
| |
 |
|
| |
Dimensions:
Weight:
|
87x266x320mm (power module only)
<6.0kg (power module only)
|
|
| |
|
|
|
| |
|
|
|
| |
 |
|
| |
Cooling:
Temperature:
Humidity:
|
Natural convection (fan-cooled option)
-25°C to +70°C (operating)
-25°C to +50°C (full power range)
55% power at +70oC
-40oC to +70oC (transport/storage)
0 to 100% RH condensing
|
|
| |
|
|
|
| |
|
|
|
| |
 |
|
| |
Green LED
Yellow LED
Red LED
|
On line – continuously on
Standby – blink
Alarm – flashing
Constant voltage – continuously on
Shut-down – continuously on
|
|
| |
Alarm conditions:
Output voltage high
Output voltage low
Output current low
Power limit
Mains out of range
Internal temperature high
Output voltage too high *
Primary converter switched off *
Secondary converter fault *
Voltage reference fault *
Temperature sensor fault *
Note: * indicates shut-down |
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
|
| |
|
|
| |
|
|
|
| |
|
|